2gig Technologies pad1 Installing Manual
GETTING STARTEDTo enter the control panel’s System Configuration module toprogram sensor zones and modify settings:1. At Home screen, tap logo in lower-right corner.Enter: Master Installer Code.Tap: System Configuration.Or2. At Home screen:Tap: Security > Menu > Toolbox.Enter: Master Installer Code.Tap: Installer Toolbox > System ConfigurationTo navigate through questions and options in the System Configurationmodule:Tap or to scroll between options on the active screen.Tap orto move to the previous or next screen’s question.For step-by-step programming information, see the installationinstructions for the peripheral device or the control panel’sInstallation and Programming Guide from dealer.2gig.com.Q1 WIRELESS ZONE PROGRAMMING(Q1) SELECT RF SENSOR # (01 to 48)Select: RF Sensor # (01 to 48)to select the desired zone option. Thentap Select: RF Sensor # Typeto select type. Then tap Select: RF Sensor Equipment Codeto select code (see EquipmentCodes on page 4). Then tap Enter: RF Sensor # Serial Number (7 Digits) Enter the serial number orplace the control panel into learning mode by tapping Shift >Learn and then trip the sensor to transmit its serial number tothe control panel.Select: RF Sensor # Equipment Ageto select (1) New or (2) ExistingThen tap Select: RF Sensor # Loop Numberto select (1) 1, (2) 2, or (3) 3:1-Use Loop 1 for all 2GIG products (except as noted in loopsbelow)2-Thin door/window contact using internal switch3 -Flood/freeze sensors. Then tapSelect: RF Sensor # Dialer Delay (0 to 1)until desired optionConstruct: RF Sensor # Voice Descriptor Tap Insert. Then tapto scrollthe available words or enter the 3-digit code associated withthe desired word. Tap Insert again before adding another word.There is a five (5) word maximum. See Voice Descriptors onpage 4. Then tap Select: Select RF Sensor # Reports (0 to 1)to select (1) Enabled or (2)Disabled. Then tap Select: Select RF Sensor # Supervised (0 to 1)to select (1) Enabled or(2) Disabled. Then tap Select: Sensor Chime to select chime. Then tap SUMMARY OF RF SENSOR # SCREENThe Summary shows the settings for each sensor. Tap Edit Next to add thenext RF sensor, or tap Edit Current to reconfigure the current RF sensor. TapQ2 WIRED SENSOR PROGRAMMINGIf no wired sensor programming is needed, tap Skip to go to Q3 Key FobProgramming.(Q2) ENTER WIRED SENSOR # (1 thru 2)Select: Sensor (Zone) Typeuntil desired optionSelect: Equipment Age (New/Existing)until desired optionSelect: Normal Stateuntil desired option(0) Not Used, (1) Normally Closed, (2) Normally Open, or (3)Mixed with no EOL. Then tap Select: Dialer Delay (Enabled/Disabled)until desired optionConstruct: RF Sensor # Voice Descriptor Tap Insert. Then tapto scroll theavailable words or enter the 3-digit code associated with thedesired word. Tap Insert again before adding another word.There is a five (5) word maximum. See Voice Descriptors onpage 4. Then tap Select: Sensor Reports (Enabled/Disabled)until desired optionSelect: Sensor Chimeuntil desired optionSUMMARY OF WIRED SENSOR # SCREENThe Summary shows the settings for each sensor. Tap Edit Next to add thenext wired sensor, or tap Edit Current to reconfigure the current wired sensor.Tap Skip to move to Q3 Keyfob Programming.Q3 KEY FOB PROGRAMMINGIf no key fob programming is needed, tap Skip to go to Q4 Keypad Programming.(Q3) SELECT FOB # (1 to 8)Select: Fob <#> Used (0 to 1)to select (1) Disabled or (2) Enabled. Then tapSelect: Fob <#> Equipment Code to select code (see Equipment Codes onpage 4). Then tap Enter: Fob <#> Serial Number (7-Digits) Enter the serial number manually (7digits) or place the panel into learning mode by tapping Shift > Learnand then tap the Armed Away button on the key fob until the LEDilluminates and the sensor transmits the serial number.Select: Fob # Equipment Age (0 to 1)to select (0) New or (1) Existing. Thentap Select: Fob # Emergency Key (0 to 4)to select (0) Disabled, (1) AuxiliaryAlarm, (2) Audible Alarm, (3) Silent Panic, or (4) Fire. Then tap Select: Fob Can Disarm (Enabled/Disabled)until desired optionConstruct: RF Sensor # Voice Descriptor Tap Insert. Then tapto scroll theavailable words or enter the 3-digit code associated with the desiredword. Tap Insert again before adding another word. There is a five (5)word maximum. See Voice Descriptors on page 4. Then tap Select: Fob # Arm No Delay (0 to 1)to select (0) Disabled or (1) Enabled.Then tap Select: Fob # Key # Output (0 to 2)to select (0) Disabled, (1) ToggleOutput, or (2) Momentary Output. Then tap SUMMARY OF FOB # SCREENThe Summary shows the settings for each sensor. Tap Edit Next to add the nextkeyfob, or tap Edit Current to reconfigure the current keyfob. Tap Skip to move to Q4Keypad Programming.FIELD PROGRAMMING FOR COMMUNICATION(Q13) SELECT TWO-WAY VOICE (0 TO 2)Tap: Go To. Then enter 13 to select a two-way voice option.Select: Two-Way Voice (0 to 2)to select (1) Stay On Line or (2) Stay On Line,Including Fire and CO Alarms. Then tap TO SETUP CELL PRIMARY: (Q8) SELECT DIALER (0 TO 1)Tap: Go To. Then enter 08 to select the dialer.Select: Dialer (0 to 1)to select (0) Disabled. Then tap Tap: Go To. Then enter 63 to select a phone fail detect option.Select: Phone Fail Detect (0 to 1)to select (0) Disabled. Then tapTO SETUP POTS PRIMARY: (Q8) SELECT DIALER (0 TO 1)Tap: Go To. Then enter 08 to select the dialer.Select: Dialer (0 to 1)to select (1) Enabled. Then tapTap: Go To. Then enter 63 to select phone fail detect.Select: Phone Fail Detect (0 to 1)to select (1) Enabled. Then tapTap: Go To. Then enter 11 to enter the CS Phone Number.Select: CS #1 Phone Number (0-25 Digits) Enter the phone number. Then tap Tap: Go To. Then enter 12 to enter the CS Account Number.Select: CS #1 Account Number (4 Digits) Enter the account number. Then tap77-000010-001 Rev DFor technical support in the USA and Canada: 855-2GIG-TECH (855-244-4832) or visit the2GIG dealer site at dealer.2gig.com, or email us at 2gigtechsupport@linearcorp.com.For technical support outside of the USA and Canada, contact your regional distributor.Copyright © 2014 Linear LLC.Quick Programming GuideControl Panel Firmware Version 1.13Q4 KEYPAD PROGRAMMINGIf no keypad programming is needed, tap Skip to go to Field Programming forCommunication.(Q4) SELECT RF KEYPAD # (1 to 4)Select: Keypad RF Keypad # (1 to 4)to select desired keypad number. Thentap Select: RF Keypad # Used (0 to 1)to select (0) Disabled or (1) Enabled.Then tap Select: RF Keypad # Equipment Codeto select code (see Equipment Codeson page 4). Then tap If using a Wireless Keypad (2GIG-PAD1)Enter: RF Keypad 1 Serial Number (7 Digits) Enter the serial number orplace the control panel into learning mode by tapping Shift > Learnand then trip the sensor to transmit its serial number to the controlpanel.If using a Wireless Touch Screen Keypad (2GIG-TS1*)—*Not available in allregionsSelect: RF Keypad # Keypad ID (Read-Only) Tap the Learn button. Then go tothe TS1 and tap the Pair WIth Panel button. When the learningoperation succeeds, tap OK on both the panel and TS1.Select: RF Keypad 1 Equipment Age (0 to 1)to select (0) New or (1)Existing. Then tap Select: RF Keypad # Emergency Keys (0 to 1)to select (0) Disabled or (1)Enabled. Then tap Construct: RF Sensor # Voice Descriptor Tap Insert. Then tapto scroll theavailable words or enter the 3-digit code associated with the desiredword. Tap Insert again before adding another word. There is a five (5)word maximum. See Voice Descriptors on page 4. Then tap SUMMARY OF RF KEYPAD # SCREENThe Summary shows the settings for each sensor. Edit Next to add the next keypad,Edit Current to reconfigure current keypad. Tap Skip to move to Field Programmingfor Communication.Download the Control Panel Installation Guide from dealer.2gig.com. |
Related manuals for 2gig Technologies CAM-HD100
2gig Technologies EDGE Installation Manual
2gig Technologies EDGE Installation Manual
2gig Technologies Go Control Install Manual
2gig Technologies Vario Quick Install Manual
2gig Technologies WDQ PAN1345 Install Instructions Manual
2gig Technologies EDGE Manual
2gig Technologies 2GIG-CO1-345 Installation Instructions Manual
2gig Technologies GC3 User Manual
2gig Technologies GC3 User Manual
2gig Technologies GC2 User Manual
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved