2N® Helios IP Automation Configuration 1.2The 2N® Helios IP web interface helps you configure block combinations (Automation)easily. The configuration shown in the figure below corresponds to the example above.2N® Helios IP allows up to 12 blocks to be created and interconnected (regardless ofthe block type - events, actions and conditions). Multiple actions can be assigned to anevent or condition. Thus, you can create 6 actions and assign them to 6 events, orcreate 11 actions and assign them to 1 event, for example.Block Parameter SettingsSelect the required Event (Event.xxx), Action (Action.xxx) or Condition(Condition.xxx) in the Block type column. Set one or more parameters for the blocksin the respective row of the Parameters column - refer to the block describingsubsections below for the supported parameters. Separate the parameters with acolon if more parameters are required.The changes will not be executed until you press the Save button in the right-handbottom corner of the page.If you have set a parameter correctly, a green mark will appear at the end of therespective block definition row. If not (if you enter a wrong parameter name/value orfail to complete an obligatory block parameter), a red mark will appear at the end ofthe row. Move your mouse cursor to the red mark to display the Help to find the error.If all the required blocks have been configured correctly (there is a green mark onevery row), 2N® Helios IP Automation will be enabled. If there is a red mark, the 2N®Helios IP Automation function will be disabled.