16Frequently Asked Questions Regarding Keypad Function• Can any of the switches be activated permanently?Yes, the additional switch can be activated by one password and deactivated byanother.• Is it possible to arrange for the switch to be activated during the whole call?Yes, additional switch can do it.• Is it possible to use a single command to activate one switch first and theother later?Yes, it is possible to use parameter 824, Switch 2 delay.• Can both the switches be activated at the same time?While one switch is activated, the other can be activated by another password. Youcan also use parameter 824, Switch 2 delay, defining the shortest delay timepossible (1second) and a sufficiently long switch activation time.• Can I use the code lock while another person is speaking through EntryCom?Yes but this is not advisable as you should be aware that the password is privateand could contravene security.• What happens when I press a number with no pre-programmed memory whilethe button replacing function is enabled? The same as if you pressed a buttonthat is not pre-programmed: EntryCom seizes the line, beeps refusal (refer toSignalling) and hangs up immediately.• What happens if a password is identical with the memory number while thecode lock and button substituting functions are enabled? The code lockfunction has the highest priority. If, for example, the password is 33 and you press, the switch is activated instantaneously. If you press without an asterisk,the line is seized after a preset delay and the number from memory 33 is dialled.Password Selection TipsTip 1: Keyboard letters facilitate password remembering. For example, it is easier toremember a 9-letter word (e.g. crocodile) than a 9-digit number (276263453).Tip 2: It is not recommended to use such passwords as 3333. This leads to aconsiderable wear and tear of one button and an unauthorised person mayguess your password easily. It is ideal to employ all keys evenly, using severalcodes for different persons or groups.