Panasonic WH-MHF12D6E5 manuals
WH-MHF12D6E5
Table of contents
- Table Of Contents
- Table Of Contents
- Introduction
- Coefficient of Performance and performance factor
- Economical and environmentally friendly
- Heat pump system
- Heat pump
- Heat utilisation
- Water heating
- Cooling
- Systematics and overview
- Outdoor unit
- Overview
- Series
- Hydromodule
- Products, functions and technical data
- dimensional drawing
- Technical data
- Monobloc system
- Monobloc unit
- Accessories
- Extras
- Closed-loop control
- Further functions
- Safety functions
- Deactivation of heating circuits in cooling mode
- External solar thermal installation
- Aquarea Heat Pump Manager
- Smart Grid" function via the Heat Pump Manager
- Project Design
- Establishing the heating load and outside design temperature
- Sizing the Hot Water Cylinder
- Establishing the heat emitter temperatures
- Operating mode and bivalence point
- Heat pump selection
- Planning of installation room
- Room volume for bi-bloc system
- Planning heat source – air
- Capacity decrease in long refrigerant pipe runs
- Assembly conditions and minimum distances from monobloc unit
- Fastening of the monobloc unit
- Acoustics
- Sound power levels for estimation of sound pressure level
- Electrical connection
- power supply
- Connections to the inputs and outputs
- DNO and tariffs
- Hydraulic decoupling for standard pumps and high-efficiency pumps without differential pressure control
- Magnetic Particle Filter
- Pumping height and pipe network resistance
- Pumping height
- Hydraulic balancing
- Expansion vessel
- Heating water quality
- Examples
- Appendix
WH-MHF12D6E5
Table of contents
- Table Of Contents
- Table Of Contents
- Introduction
- Symbols used
- Installation sequence
- Safety instructions
- General hazard instructions for avoiding material damage
- Device overview
- Dimensions diagram
- Accessories
- Location / Installing the device
- Installation
- Opening the device
- Hydraulic installation
- Electrical installation
- Mains connections
- Inputs and outputs (external interfaces)
- Installing the wired remote control
- Laying concealed cables
- Laying visible cables
- Connection to the compact unit
- Commissioning
- Setting the standard pump
- Handover and instruction
- Programming
- special functions
- Maintenance
- Visual inspection of the circuit board
- Checking the RCD
- Venting the system/Checking the quick vent
- Appendix
- commissioning report
- Handover report
- Error codes
WH-MHF12D6E5
Table of contents
- technical support
- Table Of Contents
- Table Of Contents
- Introduction
- Split systems
- Tools required
- Installation sequence
- Safety instructions
- General hazard instructions for avoiding material damage
- General further information
- Device overview
- Split systems: Hydro module
- Dimensions diagram
- Split systems: Outdoor units
- Accessories
- Location / Installing and fastening the devices
- Split systems: Height and length limitations
- Installation
- Fastening the hydro module
- Wall penetration for split systems
- Opening the device
- Hydraulic installation for monobloc systems
- Installing the heating and refrigeration circuits for split systems
- Connecting the water pipes to the hydro module
- Connecting the refrigerant pipes to the hydro module
- Condensate outlet of the hydro module
- Connecting the hydro module and the outdoor unit (refrigerant circuit)
- Condensate outlet of the outdoor unit
- Evacuating the refrigerant circuit
- Electrical installation
- Mains connections
- Inputs and outputs (external interfaces)
- Connections
- Split systems: Electrical connection between hydro module and outdoor unit
- Installing the wired remote control for monobloc systems
- Laying concealed cables
- Laying visible cables
- Connection to the monobloc unit
- Commissioning
- Preparing split systems for commissioning
- Setting up the water pump
- Setting the high efficiency pump
- Handover and instruction
- Programming
- setting the operating mode
- special functions
- Commissioning report
WH-MHF12D6E5
Table of contents