Toshiba TOSVERT VF-P7 manuals
TOSVERT VF-P7
Table of contents
- instruction manual
- safety precautions
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- read this section first
- names and functions
- main circuit, control power supply and control circuit terminal boards
- notes on the application of inverters
- notes on inverters
- influences of leakage currents and measures against it
- installation environment
- installation place
- cautions as to wiring
- standard connection
- explanation of terminals
- control circuit terminals (sink logic(minus common)
- serial rs485 communication connector
- operating the inverter
- control modes of the vf-p7 inverter
- simple operation of the vf-p7 [1] [speed control mode
- frequency setting
- operation from the control panel
- the outline of pid control
- settings of pid control
- adjustment of pid control
- how to set extended parameters
- searching for changed parameters and changing their settings again
- resetting all parameters to the factory default settings at a time
- explanation of the basic parameters
- manually setting the acceleration and deceleration times
- increasing starting torque/ energy-saving operation mode
- selecting an operation mode
- setting and calibrating meters
- factory default setting
- forward/reverse run selection (for the panel control only)
- upper and lower limit frequencies
- control mode selection
- switching between speed control and torque control
- torque reference
- manual torque boost
- preset-speed operation (15 speeds)
- extended parameters
- putting out signals of arbitrary frequencies
- selection of input signals
- assigning priority to the terminal board in panel operation mode
- binary/bcd signal selection(expansion tb option unit)
- selection of terminal functions
- changing output terminal functions
- torque limit switching
- speed/torque command gain and bias
- setting frequency command characteristics
- operation frequency
- dc injection braking
- motor shaft fixing control
- zero-speed stop mode selection
- jog run
- jump frequency - jumping resonant frequencies
- pwm carrier frequency
- NOTICE
- retry function
- dynamic (regenerative) braking - to urgently stop the motor
- Connection
- adjusting the output voltage and voltage compensation
- prohibiting the reverse operation
- Operating
- function for crane/hoist
- pid control
- setting motor constants
- Basic
- torque control
- torque reference filter
- speed limits in torque control mode
- torque bias and load sharing gain
- torque limit
- acceleration and deceleration patterns
- switching of acceleration/deceleration #1, 2, 3 and
- parameter setting
- pattern run
- protection functions
- emergency stop
- action at low currents
- cooling fan control mode selection
- uv stall level
- special analog input
- meter output
- control panel parameters
- display the motor speed and the load speed
- changing items displayed in status monitor mode
- selecting a control panel stop pattern
- canceling pid control in panel operation mode
- restricting or prohibiting key operation
- communication function (rs485/common serial)
- using the rs485 port fitted as standard
- Operation with external
- analog input filter
- setup of external speed command (analog signal)
- setup by analog input signals (rr terminal)
- setup by analog input signals (vi/ii terminal)
- setup by analog input signals (rx terminal)
- monitoring operation status
- changing status monitor function
- indication in trip status
- indication of alarm, pre-alarm, etc
- selection of peripheral devices
- installation of electromagnetic contactor
- installation of overload relay
- application and functions of options
- optional add-on cassettes
- board options
- before installing optional add-on cassette or board option
- Table of parameters
- Specification
- external dimensions and mass
- outline drawings
- cause of trip, warning indication (in detail and countermeasures)
- method of resetting causes of trip
- in the case motor does not run in spite of no trip message appearing
- how to check other troubles
- Regular
- periodical inspection
- when making a service call
- Warranty
- when disposing the inverter