Siemens FDA241 manuals
FDA241
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- About this document
- Applicable documents
- Technical terms
- Revision history
- Safety
- Safety regulations for the method of operation
- Standards and directives complied with
- Structure and function
- Details for ordering
- Product version ES
- Setup
- Front indicator
- Internal indicator
- Interface card
- External power unit and batteries
- Pipe system
- Water trap in the pipe system
- Parameter settings
- Danger levels
- Test mode
- Standalone operation
- Battery FA2003-A1 (12 V, 7 Ah, VdS)
- Planning
- Parameter Sets
- Power supply
- Determining the batteries
- Limits to planning
- Environmental influences
- Mounting / Installation
- Opening and closing the housing cover when the power supply is switched on
- Removing and installing the housing cover when the power supply is switched off
- Removing and installing the housing cover when the power supply is switched on
- Installation position and space requirements
- Mounting
- Fastening on a level substructure
- Connecting the pipe system to the aspirating smoke detector
- Installing communication transponder FDCC221S
- Installation
- Smoke 4...20 mA' analog output
- Configurable 'GPI' input
- Dust' relay output for dust value (with FDA241 only)
- PreAlarm' relay output for pre-alarm
- Connecting to the detector line with the FDCC221S
- Connection to input/output module
- Configuration
- Commissioning
- Standalone application
- Functional testing of the system
- Functional testing of the system with the standalone option
- Testing the indication of faults on the front indicator/internal indicator
- Testing the airflow
- Testing the response time
- Checking and testing the power supply units
- Normalization
- normal operation
- Maintenance / Repair
- Communication with the aspirating smoke detector
- Resetting status displays and relay outputs (standalone option)
- Performance check
- Maintenance and cleaning intervals
- Event memory
- Faults
- Table of faults
- Fault analysis
- Specifications
- Dimensions
- Annex
- Index
FDA241
Table of contents
- Table Of Contents
- Table Of Contents
- About this document
- Technical terms
- Revision history
- Safety
- Safety regulations for the method of operation
- Standards and directives complied with
- System description
- Air aspiration variants
- Typical installation in false floors or channels
- Air aspiration via capillary tubes
- Primary and secondary air intake
- Room protection
- Air aspiration system
- Equipment protection
- Water trap in the pipe system
- ASD filter box in the pipe system
- Components of the pipe system
- Branches and bends
- Fastenings
- Blowing-out unit
- Planning
- Site survey
- Designing the pipe system
- Application of standards for conventional detectors
- Network for monitored area
- Topology of the pipe system
- Pipe system
- Limits to planning
- Determining the sensitivity
- Length changes in the pipe system due to a change in temperature
- Installing pipes on the ceiling (standard)
- Installing pipes in false floors or channels
- Installing upright stand pipes
- Ambient conditions
- Mounting/Installation
- Installing the pipe system
- Trimming the pipes
- Connecting pipes and fittings
- Installing end caps
- Drilling the aspirating holes
- Index