Toshiba ESTUDIO170F manuals
ESTUDIO170F
Table of contents
- NOTICE TO USERS
- LASER SAFETY INFORMATION
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- FEATURES
- CARE AND MAINTENANCE
- INTRODUCTION
- Rear View
- OPERATION PANEL
- function keys
- SETUP
- Select a Desirable Location
- FACSIMILE MACHINE INSTALLATION
- Recording Paper Exit Tray
- Recording Paper Tray
- INITIAL PRINTING SUPPLIES INSTALLATION
- Recording Paper Installation (Bypass Tray)
- Recording Paper Installation (Optional Recording Paper Tray)
- Drum Unit and Toner Cartridge Installation
- PRINTING SUPPLIES REPLACEMENT
- Drum Unit Replacement
- QUICK START
- USER INTERFACE OPERATION
- Character Entry
- INITIAL SETUP
- Language Selection
- Date and Time Setting
- Terminal ID Setting
- Dial Type Setting
- DEVICE CONFIGURATION
- Ringer Volume Adjustment
- Alarm Tone Volume Adjustment
- Key Touch Tone Volume Adjustment
- Monitor Volume Adjustment
- Power Saver Operation
- Department Code Setting
- Department Code Maintenance
- Account Codes Setting
- Line Monitor Default Setting
- Receive Interval Setting Operation
- ECM Default Setting
- Sort Copy Setting
- Setting Redial (Interval and Counter)
- Reception Mode Default Setting
- Copy Reduction Setting
- BASIC FUNCTIONS
- One Touch Dialer Registration
- Group Number Registration
- TRANSMIT CONFIGURATION
- Document Loading
- Scan Resolution Setting
- Contrast Setting
- Default Setting for Document Mode (Resolution and Contrast)
- COPYING
- Copying Procedure
- DIALING METHODS
- Abbreviated Dialing
- Alphabet Dialing
- Keypad Dialing
- TRANSMITTING
- Memory Transmission Procedure
- Direct Transmission
- Temporary Direct Transmission
- On-hook Transmission (Monitor Speaker Dialing)
- Redialing
- Manual Redialing Jobs in Memory
- RECEIVING
- TEL/FAX Auto Switching Mode
- Selecting the Reception Mode
- COMMUNICATION STATUS
- CANCELLING A COMMUNICATION JOB
- ADVANCED FUNCTIONS
- Multi-Key Quick Broadcast Transmission
- RELAY TRANSMISSION
- Relay Transmission Originating Procedure
- POLLING & MAILBOX COMMUNICATIONS
- Open Mailbox (ITU-T Compatible)
- Simple & Security Polling Reservation
- Multi Mailbox Polling Reservation
- Simple & Secure Polling
- Multi-Address Polling
- MAILBOX (ITU-T Compatible)
- Deleting a Mailbox
- Sending a Document to a Mailbox (Remote Hub)
- Reserving a Document to a Mailbox (Local Hub)
- Retrieving (Polling) a Document from a Mailbox (Remote Hub)
- Printing a Document from a Mailbox (Local Hub)
- Cancelling Documents in a Mailbox (Local Hub)
- ADVANCED TRANSMISSION FUNCTIONS
- Account Code Entry
- Chain Dialing
- Default Setting for Memory Transmission
- Default Setting for Security Transmission
- Cover Sheet Registration
- Setting Recovery Transmission
- TTI (Transmit Terminal ID) Print
- Send after Scan Default Setting
- Document Length Setting
- PIN Mask
- ADVANCED RECEPTION FUNCTIONS
- Secure RX Activation Period Setting
- Memory Reception Setting
- Reception-Reduction Setting
- Reception-Discard Setting
- Reverse Order Printing Setting
- Privileged Reception
- RTI (Remote Terminal ID) Print
- Secure RX Temporary Stop
- TRANSMISSION OPTIONS
- Disabling ECM Temporarily
- Dialing with Sub-Address
- Enabling or Disabling Send after Scan Temporarily
- Attaching or Printing a Cover Sheet
- Delayed Communication (Time Designation)
- Priority Transmission
- Sending Recovery Transmission
- Low Speed Transmission
- Line Monitor
- Setting the Page Count
- Communication Report Print
- LISTS AND REPORTS
- Direct Transmission Report Setting
- Memory Transmission Report Setting
- Multi-Address Report Setting
- Multi-Polling Report Setting
- Relay Originator Report Setting
- Reception List Settings
- LIST AND REPORT PRINT FORMAT AND PRINTING PROCEDURE
- Transmission Report
- Memory Transmission Report
- Reservation List
- Multi-Address Transmission Report
- Multi-Polling Report
- Relay Send Originator Report
- Mailbox Reception Report
- Mailbox (ITU-T Compatible F-code Communication) List
- Department Control List
- Preset Dialing Number Lists
- Abbreviated Dial Number List
- One Touch Number List
- Group Number List
- Address Book List
- Function List
- Menu List
- Power Failure List
- Error Messages
- Paper Jam Error Codes
- Error Codes Printed on Reports
- Transmission Problems
- Reception Problems
- Clearing a Document Jam
- Clearing a Recording Paper Jam
- When the Recorded Image is not Clear
- Recording Unit Cleaning Procedure
- AUTO TEST
- INDIVIDUAL TEST MODE
- ADF TEST
- KEY TEST
- LED TEST
- LCD TEST
- SPEAKER TEST
- SENSOR TEST
- PRINT TEST
- TONER IC TEST
- TEST RESULT
- REMOTE SERVICE
- SPECIFICATIONS
- SUPPLIES
- INDEX
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
ESTUDIO170F
Table of contents
- NOTICE TO USERS
- LASER SAFETY INFORMATION
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- FEATURES
- CARE AND MAINTENANCE
- INTRODUCTION
- Rear View
- OPERATION PANEL
- function keys
- SETUP
- Select a Desirable Location
- FACSIMILE MACHINE INSTALLATION
- Recording Paper Exit Tray
- Recording Paper Tray
- INITIAL PRINTING SUPPLIES INSTALLATION
- Recording Paper Installation (Bypass Tray)
- Recording Paper Installation (Optional Recording Paper Tray)
- Drum Unit and Toner Cartridge Installation
- PRINTING SUPPLIES REPLACEMENT
- Drum Unit Replacement
- QUICK START
- USER INTERFACE OPERATION
- Character Entry
- INITIAL SETUP
- Language Selection
- Date and Time Setting
- Terminal ID Setting
- Dial Type Setting
- DEVICE CONFIGURATION
- Ringer Volume Adjustment
- Alarm Tone Volume Adjustment
- Key Touch Tone Volume Adjustment
- Monitor Volume Adjustment
- Power Saver Operation
- Department Code Setting
- Department Code Maintenance
- Account Codes Setting
- Line Monitor Default Setting
- Receive Interval Setting Operation
- ECM Default Setting
- Sort Copy Setting
- Setting Redial (Interval and Counter)
- Reception Mode Default Setting
- Copy Reduction Setting
- BASIC FUNCTIONS
- One Touch Dialer Registration
- Group Number Registration
- TRANSMIT CONFIGURATION
- Document Loading
- Scan Resolution Setting
- Contrast Setting
- Default Setting for Document Mode (Resolution and Contrast)
- COPYING
- Copying Procedure
- DIALING METHODS
- Abbreviated Dialing
- Alphabet Dialing
- Keypad Dialing
- TRANSMITTING
- Memory Transmission Procedure
- Direct Transmission
- Temporary Direct Transmission
- On-hook Transmission (Monitor Speaker Dialing)
- Redialing
- Manual Redialing Jobs in Memory
- RECEIVING
- TEL/FAX Auto Switching Mode
- Selecting the Reception Mode
- COMMUNICATION STATUS
- CANCELLING A COMMUNICATION JOB
- ADVANCED FUNCTIONS
- Multi-Key Quick Broadcast Transmission
- RELAY TRANSMISSION
- Relay Transmission Originating Procedure
- POLLING & MAILBOX COMMUNICATIONS
- Open Mailbox (ITU-T Compatible)
- Simple & Security Polling Reservation
- Multi Mailbox Polling Reservation
- Simple & Secure Polling
- Multi-Address Polling
- MAILBOX (ITU-T Compatible)
- Deleting a Mailbox
- Sending a Document to a Mailbox (Remote Hub)
- Reserving a Document to a Mailbox (Local Hub)
- Retrieving (Polling) a Document from a Mailbox (Remote Hub)
- Printing a Document from a Mailbox (Local Hub)
- Cancelling Documents in a Mailbox (Local Hub)
- ADVANCED TRANSMISSION FUNCTIONS
- Account Code Entry
- Chain Dialing
- Default Setting for Memory Transmission
- Default Setting for Security Transmission
- Cover Sheet Registration
- Setting Recovery Transmission
- TTI (Transmit Terminal ID) Print
- Send after Scan Default Setting
- Document Length Setting
- PIN Mask
- ADVANCED RECEPTION FUNCTIONS
- Secure RX Activation Period Setting
- Secure RX Temporary Stop
- Memory Reception Setting
- Reception-Reduction Setting
- Reception-Discard Setting
- Reverse Order Printing Setting
- Privileged Reception
- RTI (Remote Terminal ID) Print
- TRANSMISSION OPTIONS
- Disabling ECM Temporarily
- Dialing with Sub-Address
- Enabling or Disabling Send after Scan Temporarily
- Attaching or Printing a Cover Sheet
- Delayed Communication (Time Designation)
- Priority Transmission
- Sending Recovery Transmission
- Low Speed Transmission
- Line Monitor
- Setting the Page Count
- Communication Report Print
- LISTS AND REPORTS
- Direct Transmission Report Setting
- Memory Transmission Report Setting
- Multi-Address Report Setting
- Multi-Polling Report Setting
- Relay Originator Report Setting
- Reception List Settings
- LIST AND REPORT PRINT FORMAT AND PRINTING PROCEDURE
- Transmission Report
- Memory Transmission Report
- Reservation List
- Multi-Address Transmission Report
- Multi-Polling Report
- Relay Send Originator Report
- Mailbox Reception Report
- Mailbox (ITU-T Compatible F-code Communication) List
- Department Control List
- Preset Dialing Number Lists
- Abbreviated Dial Number List
- One Touch Number List
- Group Number List
- Address Book List
- Function List
- Menu List
- Power Failure List
- TROUBLESHOOTING
- Paper Jam Error Codes
- Error Codes Printed on Reports
- Transmission Problems
- Reception Problems
- Clearing a Document Jam
- Clearing a Recording Paper Jam
- When the Recorded Image is not Clear
- Recording Unit Cleaning Procedure
- USER TEST MODE
- INDIVIDUAL TEST MODE
- ADF TEST
- KEY TEST
- LED TEST
- LCD TEST
- SPEAKER TEST
- SENSOR TEST
- PRINT TEST
- TONER IC TEST
- TEST RESULT
- REMOTE SERVICE
- SPECIFICATIONS
- SUPPLIES
- INDEX
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
ESTUDIO170F
Table of contents
- quick start guide
- Table Of Contents
- NOTICE TO USERS
- PREFACE
- DISCLAIMER NOTICE
- SOFTWARE LICENSE AGREEMENT
- limited warranty
- TRADEMARKS AND COPYRIGHT
- INTRODUCTION
- ITEMS INCLUDED WITH THE PRODUCT
- ABOUT THE MANUALS
- ABOUT THE CD-ROM
- SETUP FLOW
- SELECT A DESIRABLE LOCATION
- FACSIMILE MACHINE INSTALLATION
- recording paper exit tray
- document support
- document exit tray
- recording paper tray
- bypass tray
- INITIAL PRINTING SUPPLIES INSTALLATION
- return to the standby mode
- recording paper installation (bypass tray)
- drum unit and toner cartridge installation
ESTUDIO170F
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Overview
- Rear View
- Operation panel
- Specifications
- Recording System
- Transceiver
- Telephone Functions
- Printer Interface
- Others
- Power Source/Size/Weight/Noise Level
- Software Performance Table
- Installation
- Preparation
- Installation Location
- Selecting the Location for Recording Paper Storage
- Unpacking
- Procedure
- Packing List
- Accessories
- Hardware Options
- Attaching Hardware Options
- Connecting to the Power and Telephone Lines
- Memory Clear
- Country/Region Setting Operation
- Country/Region setting of NCU PBA by FG harness
- Remarks on Moving the Machine
- Function Settings
- Initial Setup
- Machine Settings
- Scanner & Printer
- TX Settings
- Automatic Supply Order
- RX Settings
- Report and List Options
- Service Settings in Test Mode
- FUNC 0-39
- TEL FUNC 0-8
- UAD 0-19
- EX TYPE
- ACC DGT 1-2
- PC FUNC 0-7
- Mechanical Description
- Transmission Section
- Components of Transmission Section
- Reception Section
- Components of Reception Section
- Laser Exposure Section
- Process Unit
- Fusing Section
- Paper Pickup Section
- Exit Section
- PBA Outline and Sensor Functions
- PC Board Layout
- Connector Layout of PC Board
- NCU PBA
- LVPS
- HVPS
- Optional tray PBA
- Sensors
- Table of Sensors
- Function of Each sensor
- Circuit Description
- Circuit Connection Diagram
- Block Diagram
- PBA Major Device Diagrams
- Power Supply Table
- Flow of Image Signals
- Facsimile Reception
- Copy
- PC Interface
- MAIN PBA
- Memory Circuit
- Scanning Control Circuit
- LSU Drive Circuit
- Fuser Control Circuit
- Reset Circuit
- Super Power Save Circuit
- Toner Empty Detect Circuit
- RX Motor Drive Circuit
- TX Motor Drive Circuit
- Fan Motor Drive Circuit
- Document Detect Circuit
- Paper End Detect Circuit
- Paper Jam Detect Circuit
- Solenoid Drive Circuit
- Cover Open Detect Circuit
- PC I/F Circuit
- Line Path Switching Control Circuit
- Dial Pulse Generation Circuit
- Line Current Detect Circuit
- CI Detect Circuit
- Line Monitor Circuit
- Hook Detect Circuit (US/CA models and SG/HK models only)
- External TEL Control Circuit (EU/AU models only)
- OPERATION PANEL PBA
- Power Supply Voltage Generation Circuit
- Stabilizing Circuit
- Overvoltage Protection Circuit
- Heater Drive Circuit
- TEL PBA (US/CA models: Option, SG/HK models: Standard)
- Removal/Replacement/Adjustment
- Disassembly and Reassembly
- PBA Block
- Top Block
- Base Block
- Optional Recording Paper Tray Block
- Adjustment and Setting
- Country/Region Setting
- Lubrication
- Lubrications Points
- Dialing and Communication Procedure
- TX mode selecting procedure
- Signal Format and Communication Procedure
- Communication by binary signals
- High-speed Transmission Procedure
- Preventive Maintenance
- How to Check, How to Clean
- Troubleshooting
- AUTO TEST [MENU], [9], [1]
- INDIVIDUAL TEST [MENU], [9], [2]
- TEST RESULT LIST [MENU], [9], [3]
- SERVICE MODE
- FUNCTION TEST (In SERVICE MODE only) [MENU], [9], [4]
- MAINTENANCE (In SERVICE MODE only) [MENU], [9], [5]
- SERVICE LIST (In SERVICE MODE only) [MENU], [9], [6]
- Telephone Screening
- Flow chart recommended for field service
- Flow chart recommended for telephone screening
- Initial Checks
- Checking by self-diagnostic functions
- Trouble Analysis
- Power-ON is not possible
- Document feed error
- Recording paper feed error
- Copying error
- Poor print quality
- Updating the Firmware
- Download data from the PC
- Appendix
- Error Count List
- Function List for Maintenance
- Drum Unit
- Memory Dump List
- User Function Setting Initial Value List