Mitsubishi Electric A800 manuals
A800
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Applicable inverter model
- Operation panel indication
- PLC function specifications
- System configuration
- Operations of PLC function (Pr.414, Pr.415, Pr.498, Pr.1150 to Pr.1199)
- Prior to creating sequence programs
- Sequence program execution
- Setting the communication parameter
- Writing sequences programs
- Device map
- Internal relay (M) device map
- Special register
- Special registers to monitor and control inverter status
- Data read by controlling read command (from OFF to ON)
- Data writing method by controlling write command (from OFF to ON)
- Inverter operating status control
- Inverter parameter access error (SD1150)
- User-defined error (SD1214)
- Read/Write method of inverter parameters
- Writing inverter parameters
- User area reading/writing
- Analog I/O function
- Pulse train input function
- PID control
- Clearing the flash memory of the PLC function
- Constant scan
- CC-Link communication
- Function block diagram
- CC-Link parameter
- CC-Link I/O specifications
- I/O signals when the double setting is set in CC-Link Ver.2 (Pr.544 = "112")
- I/O signals when the quadruple setting is set in CC-Link Ver.2 (Pr. 544 = "114")
- I/O signals when the octuple setting is set in CC-Link Ver.2 (Pr. 544 = "118 or 128")
- Buffer memory
- Remote input signals Pr.544 = "100" (inverter (FR-A8NC) to master station)
- Remote registers Pr.544 = "100" (master station to inverter (FR-A8NC))
- Remote registers Pr.544 = "100" (inverter (FR-A8NC) to master station)
- Sequence program
- Overview
- RUN/STOP operation
- Programming language
- Function block (FB)
- Operation processing method of the PLC function
- I/O processing method
- Response delay in refresh mode
- Scan time
- Values that can be used in sequence programs
- BIN (binary)
- HEX (hexadecimal)
- Explanation of devices
- Internal relay M
- Timer T
- Processing and accuracy of timers
- Counter C
- Count process in refresh mode
- Data register D
- Special relays and special registers
- Function list
- RUN/STOP method of PLC function from an external source (remote RUN STOP)
- Watchdog timer (watchdog error supervision timer)
- Self-diagnostic function
- Registering file password
- Output (Y) status settings when STOP status → RUN status
- Structure of instructions
- Bit device processing method
- Handling of numerical values
- Operation error
- Sequence instructions list
- Basic instructions
- Application instructions
- Display instruction
- How to view instructions
- Sequence instructions
- Association instruction: ladder block series connection, parallel connection ... ANB, ORB
- Association instruction operation results, push, read, pop ... MPS, MRD, MPP
- Output instruction: bit device, timer, counter
- Output instruction: device set, reset ... SET, RST
- Output instruction: rising, falling differential output ... PLS, PLF
- Shift instruction: bit device shift ... SFT, SFTP
- Master control instruction: master control set, reset ... MC, MCR
- Termination instruction: termination of main program
- Other instructions: non-processing ... NOP, NOPLF, PAGE n
- Basic instruction (16-bit)
- Comparison operation instruction 16-bit data comparison
- Arithmetic operation instruction
- Arithmetic operation instruction BIN 16-bit addition/subtraction ... +, +P, -, -P
- Arithmetic operation instruction BIN 16-bit multiplication/division ... *, *P, /, /P
- Arithmetic operation instruction BIN 16-bit data increment/decrement ... INC, INCP, DEC, DECP
- Data transfer instruction
- Data conversion instruction 2's complements of BIN 16-bit data ... NEG, NEGP
- Data conversion instructions BIN 16-bit data BCD conversions ... BCD, BCDP
- Data conversion instructions BIN 16-bit data BIN conversions ... BIN, BINP
- Basic instruction (32-bit)
- Arithmetic operation instruction BIN 32-bit multiplication/division ... D*, D*P, D/, D/P
- Arithmetic operation instruction BIN 32-bit data increment/decrement ... DINC, DINCP, DDEC, DDECP
- Data conversion instruction 2's complements of BIN 32-bit data ... DNEG, DNEGP
- Data conversion instructions BIN 32-bit data BCD conversions ... DBCD, DBCDP
- Data conversion instructions BIN 32-bit data BIN conversions ... DBIN, DBINP
- Application instructions (16-bit)
- Logical operation instruction BIN 16-bit logical AND ... WAND, WANDP
- Logical operation instruction BIN 16-bit logical OR ... WOR, WORP
- Logical operation instruction BIN 16-bit data exclusive OR ... WXOR, WXORP
- Logical operation instruction BIN 16-bit data exclusive NOR ... WXNR, WXNRP
- Application instructions (32-bit)
- Logical operation instruction BIN 32-bit logical AND ... DAND, DANDP
- Logical operation instruction BIN 32-bit logical OR ... DOR, DORP
- Logical operation instruction BIN 32-bit data exclusive OR ... DXOR, DXORP
- Logical operation instruction BIN 32-bit data exclusive NOR ... DXNR, DXNRP
- Character string output ... G. PRR, GP.PRR, UMSG
- Error code list
- How to read error codes
- APPENDIX
- data transfer instructions
Related products
FREQROL-A800 SeriesCR800-05VDCR800 SeriesMELFA CR800-RMELFA CR800-DCR800-Q SeriesCR800-R SeriesCR800-D SeriesMELFA BFP-A8787-FAT-50BMitsubishi Electric categories
Air Conditioner
Inverter
Controller
Heat Pump
Servo Drives
Control Unit
Projector
Control Systems
Fan
Refrigerator