red lion IAMS Installation Manuallines
28. SERIAL COMMUNICATIONS:Type: RS485, MODBUS RTU and ASCII modesBaud: 300, 600, 1200, 2400, 4800, 9600, 19.2K, and 38.4KFormat: 7/8 bit, odd, even and no parityTransmit Delay: Programmable. (See Transmit Delay explanation in Step 6)Transmit Enable (TXEN): (primarily for 20 mA loop converter)V OH = 10 VDC max. V OL = 0.5 VDC @ 5 mA max. current limit9. A/D CONVERTER: 16 bit resolution10. ACCURACY (including linearity): 0.1% of span11. RESOLUTION: 0.002% of span12. GAIN / OFFSET: Programmable13. RELAY OUTPUTS:Type: 2 Form A N.O. contactsRating: 5A @ 30 VDC or 250 VAC max. (resistive)1/10 HP @ 120 VAC (inductive)Response Time: 155 msec. max. to close including step response, 153 msec.max. to open.14. OUTPUT ON DELAY TIME: Programmable from 0 to 32000 sec,±0.01% - 1 sec. max.15. MEMORY: Nonvolatile E 2 PROM retains all programmable parameters.16. ENVIRONMENTAL CONDITIONS:Operating Temperature Range: -20 to +65 qCStorage Temperature Range: -40 to +85 qCOperating and Storage Humidity: 85% max. relative humidity (non-condensing) from -20 to +65 qCTemperature Coefficient: +0.01%/ qC (100 PPM qC) max.Altitude: Up to 2000 meters17. CERTIFICATIONS AND COMPLIANCE:SAFETYUL Recognized Component, File # E179259, UL3101-1, CSA 22.2 No. 1010-1Recognized to U.S. and Canadian requirements under the ComponentRecognition Program of Underwriters Laboratories, Inc.IECEE CB Scheme Test Certificate # US/5141A/UL,CB Scheme Test Report # 01ME11540-0702001Issued by Underwriters Laboratories, Inc.IEC 1010-1, EN 61010-1: Safety requirements for electrical equipmentfor measurement, control, and laboratory use, Part 1.ELECTROMAGNETIC COMPATIBILITYNotes:1. This device was designed for installation in an enclosure. To avoidelectrostatic discharge to the module in environments with static levelsabove 6 KV, precautions should be taken when the device is mountedoutside an enclosure. When working in an enclosure (ex. makingconnections, etc.), typical anti-static precautions should be observedbefore touching the module.Refer to the EMC Installation Guidelines section of this bulletin foradditional information.18. CONSTRUCTION: Case body is green high impact plastic. InstallationCategory II, Pollution Degree 2.19. CONNECTIONS: 14 AWG max.20. MOUNTING: Universal mounting foot for attachment to standard DINstyle mounting rails, including top hat (T) profile rail according to EN50022- 35 x 7.5 and - 35 x 15, and G profile rail according to EN50035 - G32.21. WEIGHT: 4.5 oz. (127.57 g)MODULE ISOLATIONThe IAMS features “4-way” signal isolation. The 4-way isolation is acombination of optical, transformer and relay barriers, providing common modevoltage (CMV) isolation to 1.5 KV for 1 minute between input, RS485, andpower supply. Isolation between relay contacts and all other inputs is 2300 Vrmsfor 1 minute.LED FUNCTIONALITYPower mains class AEnclosure class AEN 55011RF interferenceEmissions to EN 55011Level 3; 10 V/mENV 50204Simulation of cordless telephone150 KHz - 80 MHzLevel 3; 10 V/rmsEN 61000-4-6RF conducted interferenceLevel 3; 2 KV powerLevel 4; 2 KV I/OEN 61000-4-4Fast transients (burst)80 MHz - 1 GHzLevel 3; 10 V/MEN 61000-4-3Electromagnetic RF fieldsLevel 3; 8 KV air 1Level 2; 4 KV contactEN 61000-4-2Electrostatic discharge200 Hz, 50% duty cycleImmunity to EN 50082-2900 MHz ± 5 MHzCONDITION GREEN LED 2 RED LEDSPower Applied On ———Communication Received Flashing ———Respective Alarm ——— OnChecksum error Flashing FlashingCalibration Off OnBLOCK DIAGRAM |
Related manuals for red lion IAMS
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved