red lion Data Station Plus Manual
2SPECIFICATIONS1. POWER: 24 VDC ± 10%200 mA min., without expansion card1 Amp maximum with expansion card fittedMust use Class 2 or SELV rated power supply.2. COMMUNICATIONS:USB/PG Port: Adheres to USB specification 1.1. Device only using Type Bconnection.Serial Ports: Format and Baud Rates for each port are individually softwareprogrammable up to 115,200 baud.RS232/PG Port: RS232 port via RJ12COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12DH485 TXEN: Transmit enable; open collector, VOH = 15 VDC,V OL = 0.5 V @ 25 mA max.Ethernet Port: 10 BASE-T / 100 BASE-TXRJ45 jack is wired as a NIC (Network Interface Card).3. LEDs:STS – Status LED indicates condition of Data Station.TX/RX – Transmit/Receive LEDs show serial activity.Ethernet – Link and activity LEDs.CF – CompactFlash LED indicates card status and read/write activity4. MEMORY:On-board User Memory: 4 Mbytes of non-volatile Flash memory.On-board SDRAM: 2 MbytesMemory Card: CompactFlash Type II slot for Type I and Type II cards.Used for optional database storage only5. REAL-TIME CLOCK: Typical accuracy is less than one minute per month drift.Battery: Lithium Coin Cell. Typical lifetime of 10 years at 25 ºC.A “Battery Low” system variable is available so that the programmer canchoose specific action(s) to occur when the battery voltage drops belowits nominal voltage.This unit is NOT field serviceable. All work must be done by a qualifiedtechnician.6. ENVIRONMENTAL CONDITIONS:Operating Temperature Range: 0 to 50°CStorage Temperature Range: -30 to +70°COperating and Storage Humidity: 80% max relative humidity,non-condensing, from 0 to 50°CVibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Zdirection for 1.5 hours, 2 g’s.Shock According to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions.Altitude: Up to 2000 meters7. CONSTRUCTION: Case body is burgundy high impact plastic andstainless steel. Installation Category I, Pollution Degree 2.8. POWER CONNECTION: Removable wire clamp screw terminal block.Wire Gage Capacity: 24 AWG to 12 AWGTorque: 4.45 to 5.34 in/lb (0.5 to 0.6 N-m)9. MOUNTING: Snaps onto standard DIN style top hat (T) profile mountingrails according to EN50022 -35 x 7.5 and -35 x 15.10. CERTIFICATIONS AND COMPLIANCES:SAFETYUL Listed, File #E302106, UL508, CSA 22.2 No. 14-M05LISTED by Und. Lab. Inc. to U.S. and Canadian safety standardsUL Listed, File #E317425, ANSI/ISA 12.12.01-2007, CSA 22.2 No. 213-M1987LISTED by Und. Lab. Inc. to U.S. and Canadian safety standardsIEC 61010-1, EN 61010-1: Safety requirements for electrical equipment formeasurement, control, and laboratory use, Part 1.ELECTROMAGNETIC COMPATIBILITYEmissions and Immunity to EN 61326: 2006: Electrical Equipment forMeasurement, Control and Laboratory use.Notes:1. Criterion A: Normal operation within specified limits.2. Criterion B: Temporary loss of performance from which the unit self-recovers.11. WEIGHT: 15.1 oz (456.4 g)HARDWAREINSTALLATIONDIN rail should be mounted horizontally so that the unit’s ventilation holesare vertical in relation to cabinet orientation. A minimum clearance of 1 inch(25.4 mm) should be maintained above and below the unit in order to ensureproper thermal regulation.Figure 1 - Attach Data Station To DIN RailImmunity to Industrial Locations:Electrostatic discharge EN 61000-4-2 Criterion B4 kV contact discharge8 kV air dischargeElectromagnetic RF fields EN 61000-4-3 Criterion A10 V/mFast transients (burst) EN 61000-4-4 Criterion Apower 2 kVI/O signal 1 kVSurge EN 61000-4-5 Criterion Bsignalpower1kV1kV L-L,2 kV L-GRF conducted interference EN 61000-4-6 Criterion A3 V/rmsEmissions:Emissions EN 55011 Class AWARNING - DO NOT CONNECT OR DISCONNECT CABLESWHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BENON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP ANDDIAGNOSTICS AND IS NOT INTENDED FOR PERMANENTCONNECTION.WARNING - EXPLOSION HAZARD - DO NOT DISCONNECTEQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF ORAREA IS KNOWN TO BE NON-HAZARDOUS. |
Related manuals for red lion Data Station Plus
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved