6.3.1.7 System MessagesSystem Messages - Displays each occurrence andthe time they took place.6.3.1.8 MetersMeters - Displays four (4) parameter meters at one time. Each meter can display thefollowing:• Module name• Parameter Name• Real time value of the parameter and the unit of measure• Programmed Parameter value• +/- Override value (operator input)To override a parameter value, turn the associated Knob to reach the desired value. Toview the next available parameter for that module, press the Knob once. Press the Knobagain to toggle through the parameter list for each module.The Meters Soft Button toggles the meters between the 4 primaryand 4 auxiliary meters. See Section 4.8.3.2 for Meter assignments.Real Time ValueParameterNameOverride ValueProgrammedValueModule Name