9Browser Operationww Connecting the Center Modulevia a PC1 Launch the PC’s Web browser.2 Input the Center Module IP address into theaddress bar of the Web browser.Example) http://Center Module IP addressThis unit has the following default settings asthe time of shipment:IP address: 192.168.0.50Port number: 80Protocol: httpwp If the HTTP port number has changed from “80”, input[http://Center Module IP address: port number] intothe [Address bar].Example) If the port number is set to 8080:http://192.168.0.50:8080Important3 When a connection has been establishedbetween the Center Module and the PC, anauthentication pop-up screen will appear. Inputthe username and password.The following are the default setting username andpassword:Username: adminPassword: 12345wp If authentication is successful, the operation screenwill appear.wp The IP address of the Center Module can be checkedon the Center Module screen. For details, refer to theOperating Instructions .Notewp Be sure to change the username and password toensure that the system is secure. For details, see“Configuring server settings” (p. 13).Importantww Setup InstructionsThis section describes basic operation procedures to setthis unit with browser operations.121 Input the necessary information into thesettings.2 Click the [Set] button.wp The settings will not be reflected unless the [Set]button is clicked.wp Do not click the button repeatedly. Doing so mayresult in the settings being set incorrectly.Important