1.2. Touch-Current Check1 Safety Precautions1.1. General Guidelines1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated ordamaged by the short circuit.2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properlyinstalled.3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground suchas a water pipe, as shown in Figure 1.3. Use Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network.4. Check each exposed metallic part, and measure the voltage at each point.5. Reserve the AC plug in the AC outlet and repeat each of the above measure.6. The potential at any point (TOUGH CURRENT) expressed as voltage U 1 and U2 , does not exceed the following values:For a. c.: U1 = 35 V (peak) and U2 = 0.35 V (peak);For d. c.: U1 = 1.0 V,Note:The limit value of U2 = 0.35 V (peak) for a. c. and U 1 = 1.0 V for d. c. correspond to the values 0.7 mA (peak) a. c. and 2.0mA d. c.The limit value U 1 = 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for frequencies greater than 100 kHz.7. In case a measurement is out of the limits specified, there is a possibility of a shock hazard, and the equipment should berepaired and rechecked before it is returned to the customer.Figure 14TX-32LXD500 / TX-26LXD500 / TX-32LX500F / TX-32LX500P / TX-26LX500F / TX-26LX500P