6.21. Remove the Plasma panelsection from the Front frame(glass)1. Remove the front frame and the plasma panel fasteningscrew (×8 ).2. Remove the front frame and the stand brackets fasteningscrew (×6 ).3. For leaving the plasma panel from the front frame, pull thebottom of the front frame forward, lift, and remove.6.22. Replace the plasma panel(finished).1. Place the new plasma panel (finished) on the flat surface ofthe table (covered by a soft cloth), with the plasma panelsurface facing downward.2. Attach the C1-Board and the C2-Board, connect the flexiblecables (×7) from the Plasma panel to the C1-Board and C2-Board, and fix the flexible cable holders.3. Attach the Hooks (left, right) and fit the stand brackets (left,right) to the new plasma panel.4. Place the plasma panel section on the servicing stand.5. Attach the front frame and the each P.C.Board and so on,to the new plasma panel.* When fitting the front frame, be careful not to allowany debris, dust or handling residues to remainbetween the front glass and plasma panel.15TH-42PM50U