Panasonic TC-431DR Service Manual
6. Potentials,as high”as22.8 kV, are present when thisreceiver is in operation. Operation the receiver withoutthe rear cover involves.the danger of a shock hazardfrom the receiver power supply.° Servicing should not- be attempted by anyone who is not thoroughly familiarwith the precautions necessary when working on highvoltage equipment. Always discharge the anode of thepicture tube to the receiver chassis before handling thetube.7. After servicing make the. following leakage currentchecks to prevent. the customer from being exposed toshock hazards.LEAKAGE CURRENT COLD CHECK1. Unplug the AC cord and connect a Tanne between thetwo prongs on the plug.2. Turn on the receiver’s power switch:3. Measure the resistance value, with an ohmmeter,between the jumpered AC plug and each exposedmetallic cabinet part on the receiver, such as screwheads,antennas, control shafts, handle bracket, etc. ‘When theexposed metallic part has a return path. to the chassis,the reading should be between 490 kQ and 5.2 MQ.When the exposed metal does not have a return path tothe chassis, the reading must be ce,LEAKAGECURRENTHOTCHECK(Seefig. 1.)1.PlugtheACcorddirectlyintotheACoutlet.use.an isolationtransformerforthischeck.Do not2.Connecta2kQ,10 wattsresistor,inserieswithanexposedmetallicparton thesetandanearthsuchasawaterpipe.3.UseanACvoltmeter,with1000ohms/voltormoresensitivity,tomeasurethepotential acrosstheresistor.4.Checkeachexposedmetallicpart,andmeasurethevoltageateachpoint.5.ReversetheACplugintheACoutietandrepeat each oftheabovemeasurements.:6.Thepotentialatany.point shouldnot exceed1.4 voltsRMS.Incasea:measurementisoutsideof thelimitsspecified, thereisapossibility ofashock hazard, andthe receivershould berepaired:and reerieekedpetalsitis returned to the customer.TC-431DR/URTC-431DR/UR6.Spannungenvonbiszu22.8kV-sind-vorhanden,wenndieserFernseherinBetriebist.FernsehersohneaufgesetzteRiickwandbringtdieGefahreineselektrischenSchlagesvonderFernseher-Stromver-sorgungmitsich.Servicearbeitensollten.daherauchniedurch Personenversuchtwerden,dienicht’invollemUmfangmitdenSicherheitsvorkehrungenbeimUmgangmitHochspannungsgeratenvertrautsind.VorderHandhabungderBildrShreistdieAnodederBildrdhreimmerandasEmpfangerchassiszuentladen.veNachBeendenderServicearbeitensinddiefolgendenKriechstrom-Priifungendurchzufiihren,umdenKundenvorderGefahreineselektrischenSchlageszuschiitzen.MESSUNGDESKRIECHSTROMSIMABGESCHALTETEN ZUSTAND1.DenNetzkabelsteckerausderNetzsteckdoseziehenunddiebeidenSteckerstiftekurzschlieBen.2.DenGerateschalterdesFernsehgerateseinschalten.3.MiteinemOhmmeterdenWiderstandswert. zwischendem—iberbriicktenNetzkabelsteckerundZuganglichenMetaliteilamGehausedesFernsehgerates,jedemwieSchraubenképfe, Antennen, Achsender Regler,Griffassungen_usw.messen.WenneinzuganglichesMetallteileineRtickleitungzumChassishat,solltedieAnzeigezwischen240kQund5,2MQbetragen.WenneinzuganglichesMetallteilkeineRuckleitungzumChassis hat, mu die Anzeige oo betragen.MESSUNGDESKRIECHSTROMSIMEINGESCHALTETEN ZUSTAND—(SieheAbb.1)1.DenNetzkabelsteckerdirektineineNetzsteckdoseeinstecken.Fur dieseMessungkeinenTrennungstrans-formator verwenden.2.Einen 2kQ-,10-Watt-WiderstandinSeriemiteinemvonauenzuganglichenMetallteilamFernsehgerat undeinerguten Erdung,z.B.Wasserleitung, anschlieRen.3.EinWechselstrom-Voltmetermit:einemMebereichvon1000 Ohm/Volt oder: gréRerSpannung Uber den Widerstand zu messen.verwenden, um die4. Jedes zuganglich Metailteil prufen, und an jedem Punktdie Spannung messen.5. Den Netzkabelsteckereinstecken und jede der obigen Messungen wiederholen.6. Die “Spannung ‘darf an keinem der Punkte 1,4V eff.umgekehrt. in die Steckdoseuberschreiten.WirddieserWertnichteingehalten,bestehtdieGefahreineselektrischen Schlages,unddas.Fernsehgeratsolltedaherrepariertund nachgeprtuftwerden, bevoresan den.Kundenzuriickgegebenwird.Die Inbetriebnahme des’iI(|i|i1i!i‘Hot Check CircuitSchaltungsaufbau fiir Priifungim eingeschalteten ZustandTOINSTRUMENT'’SEXPOSEDMETAL PARTSANZUGANGLICHEMETALLTEILEDES TV-GERATESAC VOLTMETERWECHSELSTROM-VOLTMETER -WATER PIPE ;COLD (EARTH)KALTWASSE R-ROHRE (ERDUNG)Fig. 1X-RADIATION' WARNING: 1. The potential source of X-Radiation in TV|{{i|J|i|{I;NOTE:sets is the High Voltage section and thepicture tube,2. When using a picture tube test. jig forservice, ensure that jig is capable ofhandling 22.8 kV without causing X-Radiation.Itisimportanttouse:anaccurate periodicallycalibrated highvoltagemeter._.TurntheBrightnesscontro!fullycounterclockwise.. Set the SERVICE switch to SERVICE,3.MeasuretheHighVoltage.Themeterreadingshouldindicate228kv*iekVifthemeterindicationisout of tolerance,AvireedianeserviceandcorrectionisNrequiredtopreventthepossibility ofprematurecomponentfailure.4.TopreventanX-Radiationpossibility,itisessentialtouse the specified picture tube.HORIZONTALOSC.DISABLECIRCUIT TESTThistestmustbe madeas a finalcheck before thesetisreturnedtothecustomer.;1.Withtherearcoverremoved, supplyanominal220V ACto the set turn on the power switch.2. Set controls .Brightness, ContrastSub bright3.SupplyDCvoltagetoTPE21.4. Set the voltage to 12.4V.5.Confirmthat the shutdowncircuitoperates.yest Pevend, ae Minimum position=,Abb.1ROENTGENSTRAHLUNGACHTUNG: 1. Potentielle Quellen von Roentgenstrah-lunginFernsehgeratensindderHochspan:~:nungsteilunddieBildréhre,2.BeiBildr6hren-:Prifgertistsfur.denServiceistsicherzustel-.Verwendung — - eineslen, da es flr die Bewaltigung von 22,8 kVgeeignet ist, ohne dafs Ren ins eanyverursacht wird. -ANMERKUNG:€sistwichtig,daeinprazises,regelmafiggepriftes Voltmeter verwendet wird.1. Den Helligkeitsregler’ volistandig eintgegen dem Uhr-zeigersinn drehen.2. Den SERVICE-Schalter.stellen.in die “SERVICE”-Position3.Dieeemessen.DieAnzeigedesMeterssollte22.8kV*1 kybetragen.dieseUberschreitet,istFalls die Anzeigeoe ene sofortigeBehebung:_notig,um«dieMoglichkeitvorzeitigenKomponentenausfallszuverhiiten,4.Um_dieverhindern,isteswichtig;.danurdie vorgeschriebeneMoglichkeit von Roentgenstrahlung zuBildréhre verwendet wird,PRUFUNGDERHORIZONTAL- OSZILLATIONS-UNTERBRECHUNGS-SCHALTUNGaDieser TestmualsletztePriifungvor.derRuckgabedes.Geratesanden Kundendurchgeftihrt.werden,1.BeiabgenommenerRiickwandist“demGerat|220Nennspannungzuzufiihren,undderGerateschaltereinzuschalten.2.Die Regler wiefolgt einstellen:Helligkeits-undKontrastregler....20....«.MinimumGrundhelligkeitsregler2.2... 000000., Minimum3.Gleichstrom-VoltmeteranTPE21anschlieRen.4.DieSpannungauf12,4Veinstellen.:5.Uberpriifen, da&dieAusschalt-Schaltungfunktioniert. |
Related manuals for Panasonic TC-431DR
Panasonic TC-M29 Service Manual
Panasonic TC-P50U2 Service Manual
Panasonic TC-L38D Service Manual
Panasonic tc-p46s2 Service Manual
Panasonic TC-L37G1 Service Manual
Panasonic TC-21S1M Service Manual
Panasonic TC-L37X2 Service Manual
Panasonic TC-21S3M Service Manual
Panasonic TC-21S3M Service Manual
Panasonic TC-15LT1 Service Manual
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved