41.2. Before Repair and AdjustmentSL-NE5Disconnect AC power to discharge unit AC Capacitors (C1001, C1003, C1005, C1006 and C1018) through a 10W, 1W resistor toground.SB-NE5Disconnect AC power to discharge unit AC Capacitors (C1702, C1710, C1725, C1727 and C1728) through a 10W, 1W resistor toground.Caution:DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.After repairs are completed, restore power gradually using a variac, to avoid overcurrent.• Current consumption at AC 240V, at 50Hz in NO SIGNAL mode at volume min should be ~200 mA.1.3. Protection CircuitryThe protection circuitry may have operated if either of the following conditions are noticed:• No sound is heard when the power is turned on.• Sound stops during a performance.The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are"shorted", or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.If this occurs, follow the procedure outlines below:1. Turn off the power.2. Determine the cause of the problem and correct it.3. Turn on the power once again after one minute.Note:When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.1.4. Caution For Fuse Replacement