4. Press the key of the remote controller (“LD ” changes to “LP ” of theLCD).5. Set the laser power at 600 W±10% by using VOL+ and VOL- key of theremote controller.[Specified range: 600 W±10%]Caution:Proceeding on to the subsequent adjustment procedure with the read powerexceeding 600 W±10% will result in damage to the optical pickup.6. Set the laser power with the key of the remote controller (“LP ” changesto “LDOK ” in the LCD).7. Press the key of the remote controller (“LDOK ” changes to “T0E ” onthe LDC.8. Remove the laser power meter. Laser power adjustment is finished.[REFERENCE]We recommend you to use a sensor type laser power meter for laser poweradjustment of this set.But if available is a MD cartridge type only, follow the procedure below.1. Disassemble the unit so that only the mechanism unit and the printed circuitboard are exposed. (as shown in Fig. 8 )2. Set the laser power meter cartridge. (as shown in Fig. 8 )3. Set the battery and attach and secure the battery cover with a rubber band.(as shown in Fig. 9 )4. Follow the steps for “6.2.1. Enter the adjustment mode”. (Subsequentprocedures are the same as those for the sensor type.)Fig. 829