66 NEDXCM4040SAT2 UME-0009-028.6.2 Clock & IntegrationClock :Shows the camera internal clock frequency.(Read Only)Dividing / Counter : Setting integration time.First, choose a dividing clock from the drop-down-list-box.Next, set a counter value with the slider, edit-box or the spin-button. Then, click “Send”button.Integration Time :Shows the calculated value of integration time. ( unit : μs )Padding : Set a value with the slider, the edit-box or the spin-button. Then, click “Send”button.Padding Time :Shows the calculated value of padding time. (unit : μs )Scanrate :Shows the calculated value of the scan rate. (unit : μs )Scanrate -> Counter Calculating :Set the value in the edit-box. Then, click this button.Put the desirable scan rate value, then the counter value will be calculatedautomatically with the present values of clock, dividing and padding.