– 12 Check setting at the spray lance. Appliance ventilation.Switch on the appliance without con-nection the high-pressure hose (max. 2minutes) and run it until the water dis-charging from the high-pressure outletis free of bubbles. Switch off applianceand reconnect high-pressure hose. Check the water supply. Pull out the sieve in the water connec-tion using flat-nose pliers and clean un-der running water.Cause: Voltage reduction due to weakmains supply or when using an extensioncable. When switching on, first pull the lever ofthe trigger gun and then switch the ap-pliance switch to "I/ON". Clean high-pressure nozzle: Removedirt and debris from the nozzle bore, us-ing a needle and rinse through with wa-ter from the front. Check water flow quantity. Slight leakage from the appliance pumpis normal. If the leakage increases con-tact the authorized customer service. Use spray lance with pressure regula-tion (Vario Power).Turn the spray lance to "Mix" position. Check the settings at the dosage regu-lator for detergent. Check the detergent suction hose forkinks.We hereby declare that the machine de-scribed below complies with the relevantbasic safety and health requirements of theEU Directives, both in its basic design andconstruction as well as in the version putinto circulation by us. This declaration shallcease to be valid if the machine is modifiedwithout our prior approval.The undersigned act on behalf and underthe power of attorney of the company man-agement.Authorised Documentation RepresentativeS. ReiserAlfred Kärcher GmbH Co. KGAlfred-Kärcher-Str. 28 - 4071364 Winnenden (Germany)Phone: +49 7195 14-0Fax: +49 7195 14-2212Pressure does not build up in theapplianceAppliance does not start, motorhumsStrong pressure fluctuationsAppliance is leakingNo detergent infeedEC Declaration of ConformityProduct: High pressure cleanerType: 1.167-xxx; 1.168-xxxRelevant EU Directives2006/42/EC (+2009/127/EC)2004/108/EC2000/14/EC2011/65/ECApplied harmonized standardsEN 50581EN 55014–1: 2006+A1: 2009+A2: 2011EN 55014–2: 1997+A1: 2001+A2: 2008EN 60335–1EN 60335–2–79EN 61000–3–2: 2006+A1: 2009+A2: 2009EN 61000–3–3: 2008EN 62233: 2008Applied conformity evaluation method2000/14/EC: Appendix VSound power level dB(A)1.167-xxx 1.168-xxxMeasured: 90 92Guaranteed: 93 95Winnenden, 2013/01/01CEO Head of Approbation22 EN