Refrigerator Model:HBC-70/200(India)30MAINTENANCE SERVICE AND TROUBLE SHOOTINGRefrigerator operation current is too big and will not operate normally.There are two reasons way:First, the refrigerator stops automatically after a few seconds after starting,several minutes later it starts again and stops automatically again. With incycles like this and the motor, or starter, and thermal protection unit willburn up after a long time. The main reason is: the motor coil is shorted atsome parts.Second, the refrigerator operates a certain time after starting, but it willstop automatically before the temperature reduces before the desiredtemperature is reached. After several minutes, it will start again, and theelectricity consumption increases bad. The reason is that the insulationaround the motor windings bad.12.3 Service and technical requirements of a R134arefrigerator12.3.1 Refrigeration equipment requirementsThe compressor, condenser, evaporator, drying filter must be special forR134a refrigerator and not be confused.12.3.2 Repair equipment Requirements(1) The evacuation and fill machine is special only for R134a use.(2) Other equipment (such as pressure gauge) has no special requirements,PDF created with pdfFactory trial version www.pdffactory.com