This product requires a three-prong grounded outlet.The installer must perform a ground continuity checkon the power outlet box before beginning theinstallation to insure that the outlet box is properlygrounded. If not properly grounded, or if the outletbox does not meet electrical requirements noted(under ELECTRICAL REQUIREMENTS), a qualifiedelectrician should be employed to correct anydeficiencies.CAUTION: For personalsafety, remove house fuseor open circuit breakerbefore beginninginstallation to avoid severeor fatal shock injury.CAUTION: For personal safety, the mounting surfacemust be capable of supporting the cabinet load, inaddition to the added weight of this 63–85 lbs. (29–38 kg)product, plus additional oven loads of up to 50 lbs(23 kg) or a total weight of 113–135 lbs. (51–61 kg).CAUTION: For personal safety, this product cannotbe installed in cabinet arrangements such as an island ora peninsula. It must be mounted to BOTH a top cabinetAND a wall.NOTE: For easier installation and personal safety, it isrecommended that two people install this product.IMPORTANT – PLEASE READ CAREFULLY. FORPERSONAL SAFETY, THIS APPLIANCE MUST BEPROPERLY GROUNDED TO AVOID SEVERE ORFATAL SHOCK.The power cord of this appliance is equipped with athree-prong (grounding)plug which mates with astandard three-prong(grounding) wall receptacleto minimize the possibilityof electric shock hazardfrom this appliance.You should have the wall receptacle and circuit checkedby a qualified electrician to make sure the receptacle isproperly grounded.Where a standard two-prong wall receptacle isencountered, it is very important to have it replacedwith a properly grounded three-prong wall receptacle,installed by a qualified electrician.DO NOT, UNDER ANY CIRCUMSTANCES, CUT,DEFORM OR REMOVE ANY OF THE PRONGSFROM THE POWER CORD. DO NOT USE WITHAN EXTENSION CORD.IMPORTANT SAFETY INSTRUCTIONS3ELECTRICALREQUIREMENTSProduct rating is 120 volts AC, 60 Hertz, 15 amps and1.58 kilowatts. This product must be connected to asupply circuit of the proper voltage and frequency. Wiresize must conform to the requirements of the NationalElectrical Code or the prevailing local code for thiskilowatt rating. The power supply cord and plug shouldbe brought to a separate 15- to 20- ampere branchcircuit single grounded outlet. The outlet box shouldbe located in the cabinet above the microwave oven.The outlet box and supply circuit should be installed bya qualified electrician and conform to the NationalElectrical Code or the prevailing local code.Ensure properground existsbefore useInstallation Instructions