Installation Instructions[_ Check Ignition of Surface BurnersOperation of all cooktop burners should be checked after therange and gas supply lines have been carefully checked forleaks.Electric IgnitionSelect a top burner knob and simultaneously push inand turn to LifE position. You will hear a clicking soundindicating proper operation of the spark module. Once the airhas been purged from the supply lines, burners should lightwithin 4 seconds. After burner lights, rotate knob out of theLITE position. Try each burner in succession until all burnershave been checked.Read these instructions completely and carefully.Quality of NamesThe combustion quality of burner flames needs to bedetermined visually.(AI Yellow flumes-Call for service(BI Yellow tips onouter cones-Normal for LP gas(CISoft blueflumes--NormalfornaturalgasIf burner flames look like (A),call for service.Normal burnerflames should look like (B)or (C),depending on the type of gasyou use.With LP gas, some yellow tipping on outer conesis normal.rg] Level the Ranger_ Install the oven racks in the oven and position the rangewhere it will be installed.Raiserange(on some models)Rais_!_!i°werrange range(on some models)Z] Checkfor levelness by placing a spirit levelor a cup, partially filled with water, on oneof the oven racks. If using a spirit level,take tworeadings-with the level placed diagonally first in onedirection and then the other.r-_ Remove the warming drawer. See the Care and cleaningof the range section. The front leveling legs can beadjusted from the bottom and the rear legs can beadjusted from the top or the bottom.[] Use an open-end or adjustable wrench to adjust theleveling legs until the range is level.WARN INGlnever comp,eteiyremovethelevelingleg as the range will not be secured to theanti-tip device properly.[] After leveling the unit, slide it into final position and verifylevelness.After the range is level, slide the range away from the wallso that the Anti-Tip device can be installed.51