Chapter 77-58f) SETTINGMake various settings.1) PthTurn on or off the head pulse rank control function.Default: OFF2) RTCSet RTC (real time clock) after replacing the lithium battery on the main controller PCB.T-7-1123) PV AUTO JUDGESets ink saver mode.Default: OFFg) INITIALIZEClear the [DISPLAY] histories, [ADJUST] settings, [COUNTER] values, and other parameters.T-7-113Display DescriptionDATE yyyy/mm/dd Set dateTIME hh:mm Set timeDisplay DescriptionWARNING Initialize the history of WARNING.(All displayed contents of [DISPLAY] > [WARNING] will be initialized.)ERROR Initialize the history of ERROR.(All displayed contents of [DISPLAY] > [ERROR] will be initialized.)ADJUST Initialize the value of band adjustment (by user) and head adjustment.The automatically adjusted value will not be initialized.W-INK Initialize the remaining capacity (%) of the maitenance cartridge.(Clear [COUNTER] > [PRINTER] > [W-INK])PURGE Initialize the counter related to purge unit.(Clear [COUNTER] > [PURGE])INK-USE CNT Initialize the consumption amount of ink.(Clear [COUNTER] > [INK-USE2], and count up [COUNTER] > [CLEAR] > [CLR-INK CONSUME])CUTTER-CHG CNT Initialize the cutter unit replacement frequency.(Clear [COUNTER] > [EXCHANGE] > [CUTTER EXC.], and count up [COUNTER] > [CLEAR] > [CLR-CUTTEREXC.])W-INK-CHG CNT Initialize the maintenance cartridge replacement frequency.(Clear [COUNTER] > [EXCHANGE] > [MTC EXC.], and count up [COUNTER] > [CLEAR] > [CLR-MTC EXC.])HEAD-CHG R CNT Initialize the printhead R replacement frequency.(Clear [COUNTER] > [EXCHANGE] > [HEAD R EXC.], and count up [COUNTER] > [CLEAR] > [CLR-HEAD REXC.])HEAD-CHG L CNT Initialize the printhead L replacement frequency.(Clear [COUNTER] > [EXCHANGE] > [HEAD L EXC.], and count up [COUNTER] > [CLEAR] > [CLR-HEAD LEXC.])HDD BOX PASS. Initialize the BOX password of the hard disk drive to factory default.PARTS-CHG CNT PARTS xx xx: Unit number of consumable parts(For details, refer to "Maintenance and Inspection" > "Consumable Parts")Initialize the consumable part replacement frequency.(Clear [COUNTER] > [EXCHANGE] > [UNIT x EXC], and count up [COUNTER] > [CLEAR] > [CLR-UNIT xEXC.])PARTS COUNTER PARTS xx xx: Unit number of consumable parts(For details, refer to "Maintenance and Inspection" > "Consumable Parts")Initialize the counter amount of the consumable parts.(Clear [COUNTER] > [PARTS CNT.] > [PARTS x])* After replacing the consumable part, be sure to execute this menu.