0 2A S S E M B L Y (see page 04)ENS A F E T Y N O T E SGloves should be worn during installation to preventcrushing and cutting injuries.The product may only be used for bathing, hygienicand body cleaning purposes.The hot and cold supplies must be of equal pressures.I N S T A L L A T I O N I N S T R U C T I O N S⁄ Prior to installation, inspect the product for transportdamages. After it has been installed, no transport orsurface damage will be honoured.⁄ The pipes and the fixture must be installed, flushed andtested as per the applicable standards.⁄ The plumbing codes applicable in the respectivecountries must be observed.⁄ The drain valve must only be used as intended. It is notallowed to attach other objects to the drain valve, forexample a semi-pedestal.⁄ If the instantaneous water heater causes problems or ifyou wish to increase the water flow, the EcoSmart®(flow limiter) located behind the aerator can beremoved.T E C H N I C A L D A T AThis mixer series-produced with EcoSmart® (flow limiter)Operating pressure: max. 1 MPaRecommended operating pressure: 0,1 - 0,5 MPaTest pressure: 1,6 MPa(1 MPa = 10 bar = 147 PSI)Hot water temperature: max. 70°CRecommended hot water temp.: 65°CThermal disinfection: max. 70°C / 4 minThe product is exclusively designed for drinking water!S Y M B O L D E S C R I P T I O NDo not use silicone containing acetic acid!D I M E N S I O N S (see page 05)F L O W D I A G R A M (see page 05)S P A R E P A R T S (see page 06)C L E A N I N G (see page 07)O P E R A T I O N (see page 07)Hansgrohe recommends not to use as drinkingwater the first half liter of water drawn in themorning or after a prolonged period of non-use.