ADEMCO Counterforce CFV15P Programming Manual
– 2 –TO ENTER PROGRAMMING MODE:Local programming requires the use of an alpha keypad connected to the keypad terminals on the control.A. POWER UP, then depress [∗] and [#] both at once, within 50 seconds of powering up (if ∗98 was used to exit programmode, this method must be used to reenter program mode).ORB. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.DATA FIELD PROGRAMMING PROCEDURESTask ProcedureGo to a Data Field Press [∗] + [Field Number], followed by the required entry.Entering Data When the desired field number appears, simply make the required entry. When the last entry for a fieldis entered, the keypad beeps three times and automatically displays the next data field in sequence.If the number of digits that you need to enter in a data field is less than the maximum digits available(for example, the phone number fields *41, *42), enter the desired data, then press [∗ ] to end theentry. The next data field number is displayed.Review a Data Field Press [#] + [Field Number].Data will be displayed for that field number. No changes will be accepted in this mode.Deleting an Entry Press [∗] + [Field Number] + [∗]. (Applies only to fields ∗40–*46, *94, and pager programming fields)INTERACTIVE MODE PROGRAMMING (∗∗∗∗56, ∗∗∗∗57, ∗∗∗∗58, ∗∗∗∗79, ∗∗∗∗80, ∗∗∗∗81, ∗∗∗∗82)Press [∗] + [Interactive Mode No.] (for example, ∗56). The alpha display keypad will display the first of a series of promptsrequesting entries.Interactive Mode Used to Program∗56 Zone Programming Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 RFtransmitters.∗57 Function Key Programming Unlabeled keypad keys (known as ABCD keys) for special functions∗58 Zone Programming Same options as *56 mode, but with fewer prompts. Intended for those familiar with(Expert mode) this type of programming, otherwise *56 mode is recommended.∗79 Output Device Mapping Assign module addresses and map individual relays/powerline carrier devices∗80 Output Programming 4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggers∗81 Zone List Programming Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc.∗82 Alpha Programming Zone alpha descriptorsINITIALIZE DOWNLOAD and RESET DEFAULTS∗96 Initializes download ID and subscriber account number.∗97 Sets all data fields to original factory default values.TO EXIT PROGRAMMING MODE:∗98 Exits programming mode andprevents re-entry by: Installer Code + 8 + 0 + 0. If ∗98 is used to exit programmingmode, system must be powered down, and method A above used to enter the programming mode.See field *88 for other *98 exit lockout options.∗99 Exits programming mode andallows re-entry by: Installer Code + 8 + 0 + 0 or method 1 above.Special MessagesOC = OPEN CIRCUIT (no communication between Keypad and Control).EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds.This will revert to a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass thisdelay by pressing [#] + [0].If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear afteryou correct the programming. |
Related manuals for ADEMCO Counterforce CFV15P
ADEMCO V12C Programming Manual
ADEMCO LYNXR Programming Manual
ADEMCO VISTA-40 Programming Manual
ADEMCO VISTA-15 Programming Manual
ADEMCO VIA-30pse Programming Manual
ADEMCO VISTA-10P Programming Manual
ADEMCO Vista-32FB Programming Manual
ADEMCO VISTA-10SE Programming Manual
ADEMCO Vista-2000 Programming Manual
ADEMCO VISTA-10SE Programming Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved