ACR1255U-J1 – Reference Manual info@acs.com.hkVersion V1.07 www.acs.com.hkPage 42 of 77Where:Data Object (1 byte)Tag Data Object80h Version Data Object81h Start Transparent Session82h End Transparent Session83h Turn Off RF Field84h Turn On RF Field5F 46h TimerFF 6Dh Get ParameterFF 6Eh Set ParameterManage Session Response Data ObjectTag Data ObjectC0h Generic Error status80h Version data objectFF 6Dh IFD parameter data object6.4.2.1. Start Session Data ObjectThis command is used to start a transparent session. Once the session has started, auto-polling willbe disabled until the session is ended.Start Session Data ObjectTag Length (1 byte) Value81h 00h -6.4.2.2. End Session Data ObjectThis command ends the transparent session. The auto-polling will be reset to the state before thesession has started.End Session Data ObjectTag Length (1 byte) Value82h 00h -