ABB XT201M3H/DALI Instruction Leaflet
INSTALLATION3 of 42 of 4MOUNTING SPACINGWIRING INSTRUCTIONGENERAL INFORMATIONLED Emergency down light for both open area and escape routes.Product has polycarbonate housed LED light source with low power consumption giving extendedbattery life.PRECAUTIONSCarefully read this instruction leafet before installing or using the luminaire.This leafet provides important information about the correct installation, use, maintenance anddisposal of this product. Please observe the following guidelines:1. Installation must be in accordance with European installation requirements HD 60364 andadditional local regulations.2. This product may not be modified in any way what so ever or used for a purpose or in anenvironment other than for which it is designed. Failing to observe these guidelines will invalidatethe warranty and the CE-compliance of this product.3. The luminaire is suitable for indoor use only4. Before installing the luminaire, the supply must be isolated.5.The luminaire should be connected to the voltage equivalent to that indicated on the type labelSERVICE & OPERATIONNormal Operation: The green indicator light on face plate stays on. The LED will go out if the mainssupply fails, the internal charger malfunctions, or the unit is in test mode.Battery: Sealed Ni-Cad or Ni-Mh rechargeable battery pack. Battery should be replaced when therequired duration is no longer achieved. To avoid any damage to the fixture and ensure itsperformance,the battery should be replaced with same brand and type.Test Switch: Press the test switch button, LED indicator will go out and the sign will be illuminatefrom its battery pack.WARNING:The luminaire must, under no circumstances, be covered with insulating material or similar materialonlyCommissioning Test BehaviourInitial connection of the mains supply will initiate a commissioning sequence where the battery willremain on charge and test for an uninterrupted 60 hours. Any interruption of the mains supply duringthis period will reset the counter to zero.The sequence is : to charge for 24hours. Having fully charged the battery, then execute a duration test.Upon successful completion of the duration test, the gear will perform another full charge period of24hours. After this period, it is suggested to perform a function test and then check for successfulcompletion of the function and duration tests.Therefore, after initial mains power on, it is best to leave the gear alone for 60 hours to allow the gearto complete its pre-programmed commissioning testing. During the 60 hour period, any attemptto have the gear perform a function or duration test will simply result in the requested test being'pended'. Following the commissioning test it will then perform whatever tests are pended. Meaningthat if you had pressed "start duration test", at the end of commissioning, the gear will performanother duration test and another subsequent charge period before normal operations could beresumed.Gear Behaviour After Battery Change (meaning Disconnect / Reconnect battery)After changing the battery, the gear will perform a complete commissioning sequence, as describedabove, irrespective of the condition of the battery.Function testA 5 second functional test is carried out at nominally 1 week interval.Duration testThe gear switches to battery supply with mains supply off, and runs until the batteries can no longersupply the lampThe length of time to run out is recorded in memory.A pass result indicates the battery powered the fitting and lamp for the rated period of this fitting.A full rated duration test is carried out nominally at 52 weeks intervals.In DALI mode, the start of the regular duration and function tests, is initiated by the attached controller.If the DALI controller is not available, the gear will revert to its automated settings.Maintained or Non-Maintained wiring. ACEM wiring(switchable maintained).Connect L, N and remove jumper cable andconnect switched line between SL and Lterminal.Maintained (default operation):Connect L, N and leave jumper cable connected.Non-maintained:Connect L, N and remove jumper cable.•Even escape routes•Emergency lighting factor: 1.00•Minimum illuminance on centre line: 1.00 lx•Minimum illuminance on half of escape routewidth: 0.50 lx•Diversity on the centre line max. 40 : 1•Width of escape route: 2.00 mXbYaYbXaThe spacing table is based on the followingparameters:MF 1.00 MF 0.8h(m) Xa Xb Yb Ya Xa Xb Yb Ya2.5 3.80 9.33 5.84 2.44 3.56 8.71 5.38 2.343 4.08 10.00 6.16 2.73 3.77 9.35 5.87 2.603.5 4.26 10.64 6.73 2.97 3.90 9.98 6.48 2.804 4.38 11.24 7.35 3.16 3.99 10.4 7.02 2.94 |
Related manuals for ABB XT201M3H/DALI
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved